Customization: | Available |
---|---|
Type: | Lithium Battery Charger |
Charger Type: | Electric Charger |
Still deciding? Get samples of US$ 15/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The newest design for 4A DC18RC Charger for li-ion battery Power tool for 14.4V-18V Battery Bl1830 Bl1815 Bl1430 Dc14Sa Dc18Sc Dc18Rc Dc18Ra
Compatible models
18V BL1815 BL1830 BL1840 BL1845 BL1860
14.4V BL1415 BL1430 BL1440.BL1445 BL1460
Input voltage | 100-240VAC |
Frequency | 47-63hz |
Output voltage | 20.6V~21.1 V |
Output current | 3.8~ 4.1A |
Turn on | less than 5 second |
Lifetime | more than 10000hours |
Safety standard | EN60335 |
Samples | Available |
Customized | Welcome |
INPUT CHARACTERISTICS
INPUTVOLTAGE&FREQUENCY
The charger operates input voltage from 100vac to 240vac.frequency:47-63hz.
INPUT CURRENT
The charger input current is less than 1.0A whent it works in 100vac.
OUTPUT CHARACTERS
OUTPUT VOLTAGE &CURRENT
The output voltage is over 20.6v,is less than 21.1v.output current is between3.8A and 4.1A.
TURN ON
The time for the charger turns on must less than 5 second.
PROTECTION
OVER LOAD PROTECTION
OVER TEMPERATURE PROTECTION
OVER CURRENT PROTECTION.
OUTPUT SHORTED PROTECTION
INPUT LOW VOLTAGE PROTECTION
ENVIRONMENAL CONDITION
OPERATIONG CONDITION
CHAGER OPERATES IN -5 to-40. HUMIDITY:20%-85%
STORAGE CONDITION
CHARGER STORAGES CONDITION:-20 TO 70.
COOLING METHOD
FREE CONVECTION
ELECTROMAGNETIC COMPABILITY
EMI The charger EMI meets with EN55013 & FCC PART 15B
ESD The charger is cable to withstand ESD test voltage at any point around the
encournce as be low,herein refer to IEC6100-4-2.
After applied +/-4KV contact discharge and the charger is no function erro.
After applied +/-8KV air discharge and the charger is no function erro.
RELIABILITY
MTBF
The charger shall have a minimum predicted MTBF(MIL-STD-217F) of 20000hours
at mormal operation condition and nmormal use.
LIFETIME
Lifetime of the charger shall be more than 10000hours under input rating voltae
and mean output current.
Normal operation conditions and use:
-Ambient temperature:25±2
-Stabdby(0mA): 1 hours/day
-charger operate method:(Specified normal load):23hours/day
SAFETY STANDARD
CHAGER meets with safety standard:EN60335.
DIELECTRIC WITHSTABD VOLTAGE
HI-POT:PRI-SECOND: 2KV 5MA 5S
INSULATION RESISTANCE
DC 500V PRI-SECOND INSULATION RESISRANCE